< Back to Blog

February 2020

,

Support Team

How to prepare the geometry for simulation?

Before you start a simulation, here are some instructions to prepare the model correctly and get the best out of a simulation with Ingrid Cloud. These instructions apply for Wind Load, Wind Comfort and Wind Score applications. 

The following videos display the same instructions showed  in the text:

Starting note

When the model is inserted inside the wind tunnel, Ingrid Cloud will find the lowest level of the geometry to set the point for the ground level. And the wind profile will interact with everything above that.

1-prepare-geometry-cfd-simulations

Bottom plates and ground level

Wind Comfort and Wind Load applications simulate airflow in an urban environment, so objects can’t be floating. All geometries and buildings must be placed on the same level – unless topography is being modeled, see instructions ahead.

2-geometry-preparation-ingridcloud

3-geometry-preparation-ingridcloud

Models don’t need a bottom plate. Ingrid Cloud automatically creates a “floor" under the model before starting the simulation. But if your model contains a bottom plate with "zero thickness”, and covers approximately the same area as the rest of the model, it won’t be a problem, your simulation should work. 

4-geometry-preparation-ingridcloud copy

Detailed models

Remove small details. Features such as stairs have little influence on the results at the pedestrian level. The fewer the details, the faster your simulation will finish.

If your geometries contain balconies and you are interested in analysing Pedestrian Comfort and wind dynamics specifically in the balconies, contact us before starting a simulation. 

5-detailed-model-cfd-simulations

6-detailed-model-cfd-simulations

8-close-models-cfd-simulatioms

All volumes must be closed

Since we are analysing external wind flow behaviour, all openings must be closed. Please, shut all doors, windows or any other openings.

9-close-models-cfd-simulations8-close-models-cfd-simulatioms

For Wind Comfort simulations, include surrounding buildings 

In Wind Comfort simulations, in order to better represent the flow near the area of interest, we recommend the inclusion of all surrounding buildings within a radius of at least 200 metres around the area you want to study.

Important note: Currently, the maximum model extension allowed is 1.2 km.

File format and size

Ingrid Cloud supports 11 different file formats. The best file format to use is STL, because there’s virtually no limit for file size. For all the other supported formats, a maximum of 50 megabytes is recommended.

SUPPORTED FILES:

  • STL
  • STEP
  • IFCZIP
  • DXF
  • IGES
  • OBJ
  • LAS
  • 3DS
  • IFC
  • DWG
  • ASC




Topography instructions

Create a slope connecting topography to the “ground level”10-topography-correct

Keep in mind: the edges of the model cannot be too thick or too high so that it does not disrupt or influence the airflow. The best way to set up a model for a wind tunnel simulation is by preparing a slope underneath the topography. The slope will act as a smooth path for the wind flow, allowing turbulence to be correctly predicted around your area of interest.12-topography-correct11-topography-correct copy12-topography-correct

Ingrid Cloud will take the lowest level of your geometry to automatically set the ground level. All structures modelled on top of your terrain should be contained within the slope or the terrain area.13-topography-wrong14-topography-wrong

Extension of topography and overall model size

We recommend the area covered by topography (and its slope) to be at most 20% larger than the area of interest. The maximum model extension allowed is 1.2 km. 16-area-of-interest-wrong15-area-of-interest-correct

Do you still have questions?

Here are other relevant links and if you still have a question, click the button below to talk to our team of experts. 

Wind Comfort App - Frequently asked questions
Wind Score App - Frequently asked questions
Exporting .stl files from Rhino 
Raw data application with ParaviewTalk to an expert